  material data sheet types : v28px, v76px, v301, v303, v309, v315, v317, v319, v321, v329, v335, v339 v341, v344, v346, v350, v357, v361, v362, v364, v370, v371, v373, v377, v379 v381, v384, v386, v389, v390, v391, v392, v393, v394, v395, v396, v397, v399 chemical system : a g2o | koh, naoh | zn date: 1998-05-06 voltage : 1.55 v; v28px: 6.2 v 1. type and weight cell type weight cell type weight (g) (g) v28p x 11.1 v364 0.33 v76p x 2.4 v370 0.6 v301 1.78 v371 0.61 v303 2.33 v373 0.5 v309 1.08 v377 0.39 v315 0.4 v379 0.23 v317 0.18 v381 0.9 v319 0.25 v384 0.69 v321 0.25 v386 1.78 v329 0.6 v389 1.31 v335 0.15 v390 1.32 v339 0.22 v391 0.9 v341 0.27 v392 0.69 v344 1.49 v393 1.08 v346 0.3 v394 1.04 v350 1.49 v395 0.75 v357 2.33 v396 0.55 v361 0.4 v397 0.50 v362 0.4 v399 0.75 2. ingredients a pprox. percentage (%) of total weight a ctive materials* - silver oxide - ag2o 13 - 34 - manganese dioxide - mno2 0 - 14 - zinc - zn 5 - 10 - potassium hydroxide - koh 0 - 3 - sodium hydroxide - naoh 0 - 2 main passiv - steel 26 - 57 materials* - coppe r 2 - 5 - nickel 1 - 13 - mercur y 0.2 - 0.6 - plastic 2 - 7 * all cell types are sealed button cells or button cell batteries, no chemical hazard will be posed as long as the cell remains in sealed condition. 3. safety guideline 3.1 keep out of the reach of children. if swallowed, contact a physician at once. 3.2 do not heat. nor dispose in fire. may burst or release toxic materials. 3.3 avoid forced discharge. 3.4 do not short circuit, may cause burns. 3.5 do not charge. 3.6 do not solder the battery directly. 3.7 do not disassemble, apply excessive pressure or deform. 3.8 battery compartment should provide sufficient space for battery to expand in case of abuse. 3.9 either battery compartment or battery connector should have a design that makes it impossible to place the battery in reverse polarity. 3.10 equipment intended for use by children should have tamper-proof battery compartment. 3.11 battery of different electrochemical system, grades, or brands should not be mixed. 3.12 battery disposal method should be in accordance with local and state regulations. prepared by : dr. ermisch approved by : dr.holl registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta.
material data sheet t y pe s : v4034px, v72px, v74px, v3ga, v8ga, v10ga, v12ga, v13ga, v23ga, v625 u chemical s y stem : mno2 | koh, naoh | zn date: 1998-05-0 6 1. type, voltage, capacity and weigh t cell t y p e volta g e wei g ht ( v ) (g) v4034p x 6.0 10.4 v72p x 22.5 39.0 v74p x 15.0 14.0 v3g a 1.5 0.6 v8g a 1.5 0.8 v10g a 1.5 1.1 v12g a 1.5 1.6 v13g a 1.5 1.8 v23g a 12.0 7.5 v625u 1.5 3.3 2. ingredients a pprox. percenta g e ( % ) of total wei g h t a ctive materials* - man g anese dioxide - mno 2 14 - 30 - zinc - zn 5 - 11 - potassium h y droxide - ko h 2 - 4 - sodium h y droxide - nao h 0- 0.4 main passi v - steel 40 - 60 materials* - coppe r 2 - 6 - nickel 1 - 3 - mercur y 0.2 - 0.5 - plasti c 2 - 14 * all cell t y pes are sealed button cells or button cell batteries, no chemical hazard will be posed as lon g as the cell remains in sealed condition 3. safety guidelin e 3.1 keep out of the reach of children. if swallowed, contact a ph y sician at onc e 3.2 do not heat. nor dispose in fire. ma y burst or release toxic materials 3.3 avoid forced dischar g e . 3.4 do not short circuit, ma y cause burns . 3.5 do not char g e . 3.6 do not solder the batter y directl y 3.7 do not disassemble, appl y excessive pressure or deform 3.8 batter y compartment should provide sufficient space for batter y to expand in case of abus e 3.9 either batter y compartment or batter y connector should have a desi g n that makes it impossibl e to place the batter y in reverse polarit y 3.10 equipment intended for use b y children should have tamper-proof batter y compartmen t 3.11 batter y of different electrochemical s y stem, g rades, or brands should not be mixed 3.12 batter y disposal method should be in accordance with local and state re g ulation s prepared b y : dr. ermisc h approved b y : dr.hol l registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta.
material data sheet types : v5at, v10at, v13at, v 312at, v675at chemical system : a ir cathode | koh | zn date: 1998-05-06 voltage : 1.4v 1. type, capacity and weight cell type weight (g) v5at 0.19 v10at 0.30 v13at 0.83 v312at 0.58 v675at 1.85 2. ingredients a pprox. percentage (%) of total weight a ctive materials* - catalyst 1 - 3 - zinc - zn 24 - 41 - potassium hydroxide - koh 2 - 4 main passiv - steel 29 - 50 materials* - copper 2 - 4 - nickel 2 - 6 - mercury 0.8 - 1.4 - plastic 4 - 7 * all cell types are sealed button cells, no chemical hazard will be posed as long as the cell remains in sealed condition. 3. safety guideline 3.1 keep out of the reach of children. if swallowed, contact a physician at once. 3.2 do not heat. nor dispose in fire. may burst or release toxic materials. 3.3 avoid forced discharge. 3.4 do not short circuit, may cause burns. 3.5 do not charge. 3.6 do not solder the battery directly. 3.7 do not disassemble, apply excessive pressure or deform. 3.8 battery compartment should provide sufficient space for battery to expand in case of abuse. 3.9 either battery compartment or battery connector should have a design that makes it impossible to place the battery in reverse polarity. 3.10 equipment intended for use by children should have tamper-proof battery compartment. 3.11 battery of different electrochemical system, grades, or brands should not be mixed. 3.12 battery disposal method should be in accordance with local and state regulations. prepared by : dr. ermisch approved by : dr.holl registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta.
material data sheet t y pe s : cr1216, cr1220, cr1616, cr1620, cr2016, cr2025, cr2032, cr2320, cr243 0 cr2450, cr1/3n, v28pxl, cr1/2aa, cr2/3aa, craa, cr2/3a, cr2n p chemical s y stem : mno2 | dme, pc, liclo4 | l i date: 1998-05-0 6 1. type, voltage, capacity and weigh t cell t y p e volta g e wei g ht ( v ) (g) cr1216 3.0 0.7 cr1220 3.0 0.8 cr1616 3.0 1.2 cr1620 3.0 1.2 cr2016 3.0 1.8 cr2025 3.0 2.5 cr2032 3.0 3.0 cr2320 3.0 2.9 cr2430 3.0 4.0 cr2450 3.0 6.2 cr1/3n 3.0 3.0 v28px l 6.0 8.8 cr1/2a a 3.0 11.5 cr2/3a a 3.0 15.0 cra a 3.0 21.5 cr2/3 a 3.0 17.0 cr2np 3.0 13.0 2. ingredients a pprox. percenta g e ( % ) of total wei g h t a ctive materials* - man g anese dioxide - mno 2 13 - 40 - lithium - li 1 - 3 - prop y lene carbonate - p c 3 - 9 - 1.2 dimethoxiethan - dm e 1 - 5 - lithium perchlorate - liclo 4 0.3- 1.5 main passi v - steel 33 - 74 materials* - plasti c 3 - 10 * all cell t y pes are sealed button cells, c y lindrical cells or button cell batteries, no chemical hazard will be posed as lon g as the cell remains in sealed condition 3. safety guidelin e 3.1 keep out of the reach of children. if swallowed, contact a ph y sician at onc e 3.2 do not heat. nor dispose in fire. ma y burst or release toxic materials 3.3 avoid forced dischar g e . 3.4 do not short circuit, ma y cause burns . 3.5 do not char g e . 3.6 do not solder the batter y directl y 3.7 do not disassemble, appl y excessive pressure or deform 3.8 batter y compartment should provide sufficient space for batter y to expand in case of abus e 3.9 either batter y compartment or batter y connector should have a desi g n that makes it impossibl e to place the batter y in reverse polarit y 3.10 equipment intended for use b y children should have tamper-proof batter y compartmen t 3.11 batter y of different electrochemical s y stem, g rades, or brands should not be mixed 3.12 batter y disposal method should be in accordance with local and state re g ulation s prepared b y : dr. ermisc h approved b y : dr.hol l registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta.
preliminary material data sheet t ype : lithium flat prismatic cell - lfp 7 and lfp 25 chemical system : mno2 | carbon acid ester, liclo4 | li date: 1999-08-04 1. type, voltage and weight cell type order-no. voltage weight (v) (g) lfp 7 6804 3.0 0,30 lfp25 6803 3,0 0,50 2. ingredients approx. percentage (%) of total weight active materials* - manganese dioxide 22 - lithium 3 - solution of electrolyt 11 main passiv - coppe r 37 materials* - aluminium 6 - plastic 19 * the cell is sealed, no chemical hazard will be posed as long as the cell remains in sealed condition. 3. safety guideline 3.1 keep out of the reach of children. 3.2 do not heat. not dispose in fire. may burst or release toxic materials. 3.3 avoid forced discharge. 3.4 do not short circuit. 3.5 do not charge. 3.6 do not solder the battery directly. 3.7 do not disassemble, apply excessive pressure or deform. 3.8 avoid to place the battery in reverse polarity. 3.9 battery disposal method should be in accordance with local and state regulations. prepared by : dr. ermisch approved by : dr. holl registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta.
material data sheet t yp es : v15h, v40h, v80h, v65ht, v110ht, v150h, v200h, v250h, cp300h, v300h, v350h chemical s y stem : niooh | koh | mh - rechar g eable date: 1999-03-22 volta g e : 1.2v 1. type, capacity and weight cell t yp et yp ical ca p acit y ( mah ) wei g ht (g) v15h 16 1,3 v40h 43 1,7 v80h 80 4 v65ht 70 4 v110ht 120 6 v150h 150 6 v200h 220 7 v250h 250 10 cp300h 300 11 v300h 320 12 v350h 380 13 2. ingredients app rox. p ercenta g e ( % ) of total wei g ht a ctive materials* - nickel h y droxide - ni ( oh ) 210 - h y dro g en stora g e mischmetal allo y 10 - 11 - potassium h y droxide - koh 8 passive materials* - steel 40 - 50 - metallic nickel 20 - 25 - plastic 3 * all cell t yp es are sealed button cells, no chemical hazard will be p osed as lon g as the cell remains in sealed condition. 3. safety guideline 3.1 kee p out of the reach of children. if swallowed, contact a p h y sician at once. 3.2 do not incinerate or mutilate, ma y burst or release toxic materials. 3.3 do not short circuit, ma y cause burns. 3.4 do not solder the batter y directl y . 3.5 restrict char g in g current and time to the recommended value. 3.6 observe char g in g tem p erature: 0 to +65c. 3.7 batter y com p artment should p rovide sufficient s p ace for batter y to ex p and in case of abuse. 3.8 either batter y com p artment or batter y connector should have a desi g n that makes it im p ossible to p lace the batter y in reverse p olarit y . 3.9 e q ui p ment intended for use b y children should have tam p er- p roof batter y com p artment. 3.10 batter y of different electrochemical s y stem, g rades, or brands should not be mixed. 3.11 batter y dis p osal method should be in accordance with local and state re g ulations. 4. v15h, v40h, v150h, v250h, v300h and cp300h are ul reco g nized com p onents: cate g or y bbet2, file no. mh13654. pre p ared b y : e p y tlik a pp roved b y : m kilb registered office: varta ger?tebatterie gmbh, daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/8 3 554 t h e b a t t e r y e x p e r t s this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta ger?tebatterie gmb h
material data sheet types : v400hr, v450h r chemical syste m : nimh-rechargeabl e date: 1999-03-02 voltage : 1.2v 1. type, capacity and weight cell type typical capacity (mah ) weight (g) v400h r 420 14 v450hr 460 14,5 v20hr 22 1,1 2. ingredients approx. percentage (%) of total weigh t active materials* - nickel hydroxide - ni(oh)2 10 - hydrogen storage mischmetal allo y 10 - 11 - potassium hydroxide - koh (32%) 8 passive materials * - steel 40 - 50 - metallic nickel 20 - 25 - plastic 3 * all cell types are sealed button cells, no chemical hazard will be posed as long as the cel remains in sealed condition. 3. safety guideline 3.1 keep out of the reach of children. if swallowed, contact a physician at once . 3.2 do not incinerate or mutilate, may burst or release toxic materials . 3.3 do not short circuit, may cause burns. 3.4 do not solder the battery directly. 3.5 restrict charging current and time to the recommended value . 3.6 observe charging temperature: 0 to +65c. 3.7 battery compartment should provide sufficient space for battery to expand in case of abuse . 3.8 either battery compartment or battery connector should have a design that makes it impossible to place the battery in reverse polarity. 3.9 equipment intended for use by children should have tamper-proof battery compartment 3.10 battery of different electrochemical system, grades, or brands should not be mixed 3.11 battery disposal method should be in accordance with local and state regulations prepared by :tobias mai approved by : registered office: varta ger?tebatterie gmbh, daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/8 3 553 t h e b a t t e r y e x p e r t s this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta ger?tebatterie gmbh
preliminary material data sheet types : mc 614, mc 621 chemical system : limno2 | organ. electrolyt | li date: 1999-08-03 1. type, voltage, and weight cell type order-no. voltage weight (v) (g) mc 614 60614 3.4 - 2.0 0,18 mc 621 60621 3.4 - 2.0 0,24 2. ingredients a pprox. percentage (%) of total weight a ctive materials* - lithium manganese dioxide 3 - 5 - lithium 0,2 - organ. electrolyt 5 - 9 main passiv - steel and nickel 80 materials* - plastic 8 * the cell is a sealed button cell no chemical hazard will be posed as long as the cell remains in sealed condition. 3. safety guideline 3.1 keep out of the reach of children. if swallowed, contact a physician at once. 3.2 do not heat. nor dispose in fire. may burst or release toxic materials. 3.3 avoid forced discharge. 3.4 do not short circuit, may cause burns. 3.5 restrict charging current and time to the recommended value. 3.6 do not solder the battery directly. 3.7 do not disassemble, apply excessive pressure or deform. 3.8 battery compartment should provide sufficient space for battery to expand in case of abuse. 3.9 either battery compartment or battery connector should have a design that makes it impossible to place the battery in reverse polarity. 3.10 equipment intended for use by children should have tamper-proof battery compartment. 3.11 battery of different electrochemical system, grades, or brands should not be mixed. 3.12 battery disposal method should be in accordance with local and state regulations. prepared by : dr. ermisch approved by : dr. holl registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta.
preliminary material data sheet type : lithium ion polymer flat - series flp ... chemical system : mno2 | carbon acid ester, liclo4 | li date: 1999-08-04 1. type, voltage and weight cell type order-no. voltage weight (v) (g) flp 35741-s0 66030 3.6 0,?? ... ... 3,6 0,?? 2. ingredients a pprox. percentage (%) of total weight a ctive materials* - manganese dioxide - mno2 22 - lithium - li metal 3 - solution of electrolyt 11 (carbon acid ester with liclo4) main passiv - copper 37 materials* - aluminium 6 - plastic 19 * the cell is sealed, no chemical hazard will be posed as long as the cell remains in sealed condition. 3. safety guideline 3.1 keep out of the reach of children. 3.2 do not heat. not dispose in fire. may burst or release toxic materials. 3.3 avoid forced discharge. 3.4 do not short circuit. 3.5 do not charge. 3.6 do not solder the battery directly. 3.7 do not disassemble, apply excessive pressure or deform. 3.8 avoid to place the battery in reverse polarity. 3.9 battery disposal method should be in accordance with local and state regulations. prepared by : dr. ermisch approved by : dr. holl registered office: varta ger?tebatterie gmbh daimlerstrasse 1 d-73479 ellwangen/germany tel. (+49) 7961/83-0 fax: (+49)7961/83 554 this document is the property of varta ger?tebatterie gmbh and must not be copied or disclosed to a third party without the wri tten consent of varta .


▲Up To Search▲   

 
Price & Availability of V357006449

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X